Tap Density Meter
R45,889.00 – R68,998.00Price range: R45,889.00 through R68,998.00 incl Vat
Manual Microtome
R139,988.00 incl Vat
Veterinary Electrolyte Analyser
R58,855.00 – R64,995.00Price range: R58,855.00 through R64,995.00 incl Vat
| Weight | N/A |
|---|---|
| Dimensions | N/A |
| Size | BKE-A/B/C/D, BKE-E/F/L |
SKU:
N/A
Category: Laboratory Equipment
Description
Veterinary Electrolyte Analyser
A veterinary electrolyte analyser is a diagnostic device that measures key ionic minerals (such as sodium, potassium, chloride, and ionized calcium) in animal bodily fluids.
Primary Uses in Veterinary Medicine
- Dehydration & Fluid Therapy: Assesses fluid deficits and helps veterinarians choose safe, accurate intravenous (IV) or subcutaneous fluid and electrolyte replacements.
- Critical Care & Emergency: Delivers rapid (often under a minute) bedside or in-clinic results for trauma, shock, or critically ill patients in the ICU.
- Kidney & Renal Disease: Monitors electrolyte shifts (like potassium and sodium imbalances) in acute or chronic kidney failure and tracks response to dialysis.
- Endocrine & Metabolic Disorders: Evaluates hormonal conditions (such as Addison’s disease or diabetic ketoacidosis) where electrolyte regulation is disrupted.
- Gastrointestinal Dysfunction: Detects severe ion losses caused by persistent vomiting, diarrhea, or blockages.
- Species-Specific Screening: Uses pre-set reference intervals tailored to different animals—ranging from companion pets (dogs, cats) to livestock (cattle, horses, pigs) and exotic species.
Veterinary Electrolyte Analyser
Common Measured Parameters
- Sodium (Na⁺): Regulates total body water and cellular pressure.
- Potassium (K⁺): Crucial for cardiac rhythm and normal muscle/nerve function.
- Chloride (Cl⁻): Maintains acid-base and fluid balance.
- Ionized Calcium (iCa²⁺): Active calcium vital for blood clotting, muscle contraction, and signaling.
- pH / Blood Gases: Often paired on the same platform to check acid-base status.
Veterinary Electrolyte Analyser
Feature
1. The software supports automatic potential tracking correction to ensure stable performance.
2. Automatic monitoring and filtering of tiny air bubbles to ensure measurement accuracy.
3. Wave flushing and pipeline flushing can avoid blockage and cross-contamination.
4. Power-off protection, can protect data storage, the result can be stored up to 50,000.
5. Low consumption, effectively reducing the cost of consumables.
6. 7-inch high-definition touch screen, comprehensive content display.
7. With the function of automatic fault alarm and elimination, improve work efficiency.
2. Automatic monitoring and filtering of tiny air bubbles to ensure measurement accuracy.
3. Wave flushing and pipeline flushing can avoid blockage and cross-contamination.
4. Power-off protection, can protect data storage, the result can be stored up to 50,000.
5. Low consumption, effectively reducing the cost of consumables.
6. 7-inch high-definition touch screen, comprehensive content display.
7. With the function of automatic fault alarm and elimination, improve work efficiency.
|
Model
|
BKE-A/B/C/D
|
BKE-E/F/L
|
|
Sample
|
Serum, plasma, whole blood, cerebrospinal fluid and dilute urine
|
|
|
Measuring Speed
|
≤25s
|
|
|
Analysis Method
|
Ion selective electrode(ISE)
|
|
|
Sample Volume
|
60~150μl
|
200μl
|
|
Sample Position
|
30 sample positions, 5 emergency positions(Only for BKE-B/D/F/L)
|
|
|
Injection mode
|
Manual or automatic injection can be selected(Only for BKE-B/D/F/L), BKE-A/C/E is manually injection
|
|
|
Storage
|
Up to 50,000 test results
|
|
|
Printer
|
Build-in thermal printer
|
|
|
Interface
|
RS232 port for LIS
|
|
|
Display
|
7-inch high-definition touch screen
|
|
|
Language
|
Chinese and English, other languages can be customized
|
|
|
Calibration
|
Automatic and manual calibration
|
|
|
Other Function
|
Sample volume detection
|
|
|
Power Supply
|
AC100~240V, 50/60Hz, 70VA
|
|
|
Temperature
|
+10~+40℃
|
|
|
Relative Humidity
|
≤80 %
|
|
|
Atmospheric Pressure
|
86~106kPa
|
|
Veterinary Electrolyte Analyzer
|
Model
|
BKE-A
|
BKE-B
|
BKE-C
|
BKE-D
|
|
Test Items
|
K+, Na+, Cl-
|
K+, Na+, Cl-
|
K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH
|
K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH
|
|
Sample Tray
|
No
|
Yes
|
No
|
Yes
|
|
External Size(W*D*H)(mm)
|
405*214*471
|
682*287*471
|
405*214*471
|
682*287*471
|
|
Net Weight(kg)
|
12.48
|
15.11
|
12.48
|
15.11
|
|
Package Size(W*D*H)(mm)
|
Instrument:
500*390*530 Reagent: 220*160*120, 220*160*120 |
Instrument:
500*390*720 Reagent: 220*160*120, 220*160*120 |
Instrument:
500*390*530 Reagent: 220*160*120, 220*160*120 |
Instrument:
500*390*720 Reagent: 220*160*120, 220*160*120 |
|
Gross Weight(kg)
|
Instrument: 16.08
Reagent: 1.7, 0.9 |
Instrument: 19.31
Reagent: 1.7, 0.9 |
Instrument: 16.08
Reagent: 1.7, 0.9 |
Instrument: 19.31
Reagent: 1.7, 0.9 |
Veterinary Electrolyte Analyser
Shipping & Delivery
Lead Time
- Standard Lead time: 3 - 4 working days.
- Imports: 4 - 6 Weeks
Dangerous Chemicals
Please note that an affidavit is required for the purpose of dangerous chemicals, clearly stating the intended use of the chemical.
📋
View Quotation
0
Your Quotation
Your quotation is empty.